Date: 30/11/2024
Place: Singapore
Inspector: Mustafa Tirmizey
ELEMENTS |
SIRE 2.0 REF |
OBSERVATIONS |
Process |
2.2.1 |
The last two
visits by superintendent were within 7 months, but the 2nd last and 3rd last
visits as declared in the PIQ were with a gap of more than 7 months. |
Hardware |
5.4.2 |
A screw
driver was required to open the fuel tank inspection cover for freefall
lifeboat the tank fuel level. The screwdriver was missing. |
Hardware |
5.8.1 |
Bunker line
dresser coupling and it’s nuts bolts near manifolds was heavily corroded. |
Hardware |
5.8.1 |
Electric
conduit leading to deck lamp post was corroded heavily for a length of about
2.0 M in midship area |
Hardware |
5.8.2 |
The exhaust
pipe for hydraulic power pack with temp 58 deg C was not marked with a hot
surface warning sign. |
Process |
5.8.2 |
Safety
inspection of engine room did not identify hot surfaces liable to cause burn
to human. |
Hardware |
9.1.1 |
The pressure
gauge used for mooring winch brake testing in Apr 2024 was not calibrated
before testing of winch brakes. |
Human |
9.1.1 |
OP did not
follow Company procedure to calibrate the pressure gauge of winch brake
testing kit before testing the winch brakes in Apr 2024. |
Photographs |
11.1.3 |
The photo
uploaded was not as per OCIMF guideline. |
Photographs |
11.1.42 |
Vessel was
fitted with Framo pumps but a photo was not uploaded by the operator. |