SIRE 2.0 with Inspector Mr KHALID MOUCHTAKI - 2
SIRE 2.0 REPORT
PORT : MOHAMMEDIA, MOROCCO
COMPANY : IMT
INSPECTOR: KHALID MOUCHTAKI
Vessel comment: Overall approach was very practical and no nonsense was experienced during the inspection.
Deck :
TIME TAKEN : 45 MIN
PUMPROOM : 20 MIN
CCR : 45 MIN
On deck tried out HLA ,LIFEBOAT , EMERGENCY GENERATOR
Checked very closely heating system for cargo tanks.
Very much looking for rust spots.
Checked sample locker very thoroughly for ppe msds
Pumproom very thoroughly checked cargo sea chest arrangement for securing .
Emergency escape arrangement.
Tried out bilge alarm.
Bwts system filters inspected.
CCR
Checked SSSCL very thoroughly.
Cargo plan
Loadicator testing
Cargo tank pressure alarms tried out
Questions on IG system failure
Wind criteria
Actions in various emergency
Verification on LMP,MSMP.
Overall approach was very practical and no nonsense was experienced during the inspection.