SIRE 2.0 with Inspector Arif Ayub

Date : 01-12-2024

Place: Singapore

Inspector: Arif Ayub        

ELEMENTS

 

SIRE 2.0 REF

 

OBSERVATIONS

 

Hardware

2.1.1     

A short-term ballast water management system certificate was issued on 28 Nov 2024, valid until 27 Jan 2025, due to port side BWTS was inoperative due to defective flow meter, while starboard side BWTS was functional. Above finding was also recorded in the open defect list.

 

Human 

2.8.1     

1.5.6.1- Last special survey date was inaccurate.

 

 

 

10.9.1 crane last annual and 5 yearly dates were inaccurate."

 

Human 

3.2.7     

Comprehensive mooring and anchoring audit report was not available on board, however, as per the company's internal audit procedure the scope of internal audit covers the requirements of mooring and anchoring procedures.

 

Quick Links:-

Get In Touch:-


  • Follow Us :-
×